Tauchflex FL flat, blue, Submersible pump cable
Product Application
Application:
Tauchflex-FL as a special cable
It can be used for the connection and control of Submersible pump, underwater lights, floating switches, etc. It has been verified that the submergence depth of 300 m in drinking water, production water and domestic water can be used in dry, wet and humid areas as well as outdoor environments.
Not suitable for installation in hazardous areas
CE=The product complies with EU Low Voltage Directive 2014/35/EU
Features:
Good insulation performance when submerged in water
Minimize weight increase in water
The mechanical stability of the insulation material remains unchanged even when submerged
As a connecting cable for the motor rotor, a maximum of 1000 V with protection is fixed and installed in the pipeline
Conductor: DIN VDE 0295 Class 5, fine copper wire, BS 6360 Class 5, IEC 60228 Class 5
Core insulation: EPR core insulation
Core wire color: 3-core and above, including yellow green ground wire
Cabling: The core adopts the optimal pitch and layered stranding
Tensile strength:/
Inner sheath:/
Outer sheath: PUR outer sheath
Outer sheath color: blue
Representative significance: G=with yellow green grounding wire x=without yellow green grounding wire
Working voltage: 450/750V AC and three-phase current: 413/825 V DC: 0.6/1KV
Test voltage: 2500V/15min
Dynamic bending radius: 3 x D (cable diameter<12mm) 4 x D (cable diameter>12mm)
Fixed installation radius 3xD (cable diameter<8mm) 4xD (cable diameter: 8-12mm) 4xD (cable diameter>12mm)
Mobile installation temperature: -25 ° C to+80 ° C
Fixed installation temperature: -40 ° C to+80 ° C
Underwater temperature limit+40 ° C * (recommended)+60 ° C (reduces cable life)
Static load: total cross-section X200 N/mm
Minimum insulation resistance: 20 MOhm x km